Line 47: Line 47:
 </WRAP> </WRAP>
 </WRAP> </WRAP>
 +
 ==== Image Selection Optimization Wizard ==== ==== Image Selection Optimization Wizard ====
 Automated searches for optimal image selection model start from "Image Selection Optimization" wizard. It can be opened from the "Wizards" menu. A step by step guide to the wizard is provided below. Automated searches for optimal image selection model start from "Image Selection Optimization" wizard. It can be opened from the "Wizards" menu. A step by step guide to the wizard is provided below.
 +
 === Introduction === === Introduction ===
 Before proceeding to the next steps of the wizard, processed samples must be present within the main GUI. The "curve fit residual" evaluation method will require at least 3 samples, the "leave-1-out dose estimation" method at least 4 samples.  Before proceeding to the next steps of the wizard, processed samples must be present within the main GUI. The "curve fit residual" evaluation method will require at least 3 samples, the "leave-1-out dose estimation" method at least 4 samples. 
 +
 === Select Samples === === Select Samples ===
 Sample selecting in this wizard is the same as in the "Curve Calibration" wizard. Selected samples will be used to evaluate image selection models during optimization. Enter physical doses of these samples if they are not auto-filled or if they were auto-filled incorrectly. Sample selecting in this wizard is the same as in the "Curve Calibration" wizard. Selected samples will be used to evaluate image selection models during optimization. Enter physical doses of these samples if they are not auto-filled or if they were auto-filled incorrectly.
 +
 === Select an SVM Sigma Value === === Select an SVM Sigma Value ===
 Select an SVM sigma to use for optimization. It determines dicentric chromosome distributions, which are used to calculate p-values of Poisson fit, and dicentric chromosome frequencies, which are used in the "curve fit residual" method and the "leave-1-out dose estimation" method.  Select an SVM sigma to use for optimization. It determines dicentric chromosome distributions, which are used to calculate p-values of Poisson fit, and dicentric chromosome frequencies, which are used in the "curve fit residual" method and the "leave-1-out dose estimation" method. 
 <WRAP group> <WRAP group>
 <WRAP column half> <WRAP column half>
 +
 === Configure Image Selection Model Search === === Configure Image Selection Model Search ===
 As described in the "Method" section, possible image selection models are logically categorized into 3 groups. In ADCI, users have the option to include or exclude a group in the search of optimal models. Place a checkmark beside groups that are intended to be searched. Leave undesired groups unchecked. Image selection models in checked groups will be generated according to configurations in "Image Selection Optimization Settings". As described in the "Method" section, possible image selection models are logically categorized into 3 groups. In ADCI, users have the option to include or exclude a group in the search of optimal models. Place a checkmark beside groups that are intended to be searched. Leave undesired groups unchecked. Image selection models in checked groups will be generated according to configurations in "Image Selection Optimization Settings".
Line 66: Line 71:
 </WRAP> </WRAP>
 </WRAP> </WRAP>
 +
 <WRAP group> <WRAP group>
 <WRAP column half> <WRAP column half>
Line 75: Line 81:
 </WRAP> </WRAP>
 </WRAP> </WRAP>
 +
 === Summary === === Summary ===
 Ensure your previous selections are correct on this summary screen. Note values entered on previous screens can be edited by clicking the blue button on the top left of the wizard dialog. Click “Finish” to complete the wizard and bring up the “Optimal Image Selection Model Search” dialog. Ensure your previous selections are correct on this summary screen. Note values entered on previous screens can be edited by clicking the blue button on the top left of the wizard dialog. Click “Finish” to complete the wizard and bring up the “Optimal Image Selection Model Search” dialog.
 +
 ==== Optimal Image Selection Model Dialog ==== ==== Optimal Image Selection Model Dialog ====
-<WRAP group> 
-<WRAP> 
 The automated search for optimal image selection models is performed in this dialog. A summary, including model generation configuration and evaluation method and samples, is shown in the top part. Users can check if everything is correct. The automated search for optimal image selection models is performed in this dialog. A summary, including model generation configuration and evaluation method and samples, is shown in the top part. Users can check if everything is correct.
  
Line 93: Line 99:
  
 "Report" functionality will be implemented in future version of ADCI. "Report" functionality will be implemented in future version of ADCI.
-</WRAP> +
-<WRAP>+
 {{ :file:wizard:optimalsearchdialog.png?nolink|}} {{ :file:wizard:optimalsearchdialog.png?nolink|}}
-</WRAP> 
-</WRAP> 
- 
  
-===== Searching Time =====+===== Estimate time required to perform a search =====
 The time needed to perform an image selection model optimization search depends on the number of models being searched. If the search space is relatively large, it may take hours to finish the optimization. The time required to perform a search can be estimated for certain evaluating samples. Doing so is encouraged in order to help plan a convenient time to start the search.  The time needed to perform an image selection model optimization search depends on the number of models being searched. If the search space is relatively large, it may take hours to finish the optimization. The time required to perform a search can be estimated for certain evaluating samples. Doing so is encouraged in order to help plan a convenient time to start the search. 
  
Line 109: Line 111:
 The time required in a search is also proportional to the number of evaluating samples. If the number of evaluating samples in a real search is twice the number of samples in the test search, the real search is expected to take twice as long.  The time required in a search is also proportional to the number of evaluating samples. If the number of evaluating samples in a real search is twice the number of samples in the test search, the real search is expected to take twice as long. 
  
-Finally, the 'p-value of Poisson' and 'curve fit residual' methods take approximately the same amount of time. The 'Leave-one-out' method takes longer, and is proportional to the number of evaluating samples. For example, to finish a search of 10 evaluating samples, it will be 10-time longer for 'leave-one-out' compared to 'curve fit residual' or 'p-value of Poisson'.+Finally, the 'p-value of Poisson' and 'curve fit residual' methods take approximately the same amount of time. The 'Leave-one-out' method takes longer, and is proportional to the number of evaluating samples. For example, to finish a search using 10 evaluating samples, 'leave-one-out' will take approximately 10-times longer than either  'curve fit residual' or 'p-value of Poisson'.