 ====== Quality control ====== ====== Quality control ======
-**This functionality will become available in version 1.4 of ADCI**. Quality control (QC) metrics are applied to [[main:sample | samples]] and aberrations. QC issues related to samples are visible in the sample list within the [[main:mainGUI | main GUI]]. Samples which do not meet quality control thresholds are marked with orange or yellow background color in the sample's "Identity" field. Additional quality control issues related to aberrations are colored orange and are visible in the [[main:calibrationcurve | calibration curve]] and [[main:estimatedose | dose estimation]] dialogs.+**This functionality will become available in version 1.4 of ADCI**. Quality control (QC) metrics are applied to [[main:sample | samples]] and aberrations. QC issues related to samples are visible in the sample list within the [[main:mainGUI | main GUI]]. Samples which do not meet QC thresholds are marked with an orange or yellow background color in the sample's "Identity" field. Additional QC issues related to aberrations are colored orange and are visible in the "[[main:calibrationcurve | Fit a curve]]and "[[main:estimatedose | Dose Calculator]]dialogs.
  
 ===== Edit thresholds ===== ===== Edit thresholds =====
-Each threshold observed during quality control procedures can be modified in a dialog accessed by selecting "Settings" in the menu bar, then clicking "Quality Control Thresholds".+Every threshold observed during QC procedures can be modified in a dialog accessed by selecting "Settings" in the menu bar, then clicking "Quality Control Thresholds".
  
 <WRAP group> <WRAP group>
 <WRAP half column> <WRAP half column>
 ==== Sample ==== ==== Sample ====
-  * **Minimum total images**\\ If the total number of images in a sample is less than this value, the software will report a QC issue. +  * **Minimum total images**\\ If the total number of images in a sample is less than this value, a QC issue will be reported
   * **Minimum selected images**\\ If the number of images in a sample after applying an [[main:imageselectionmodel | image selection model]] or through manual exclusion is less than this value, a QC issue will be reported.   * **Minimum selected images**\\ If the number of images in a sample after applying an [[main:imageselectionmodel | image selection model]] or through manual exclusion is less than this value, a QC issue will be reported.
 ==== Aberration ==== ==== Aberration ====
Line 21: Line 21:
  
 ===== How QC issues are reported ===== ===== How QC issues are reported =====
-QC issues related to sample image count can be found in the sample list within the [[main:mainGUI | main GUI]]. The "Fit a curve" and "Dose Calculator" dialogs take into account additional "Aberration" QC thresholds. Note manually entering an aberration in either of these dialogs will not generate a QC issue even if the manually entered values do not meet QC thresholds. For a QC issue to be reported, an aberration must be derived from an imported sample.+QC issues related to sample image count can be found in the sample list within the [[main:mainGUI | main GUI]]. The "Fit a curve" and "Dose Calculator" dialogs take into account additional "Aberration" QC thresholds. Note manually entering an aberration in either of these dialogs will not generate a QC issue even if the manually entered values do not meet QC thresholds. For a QC issue to be reported, an aberration must be derived from an imported sample. If a sample does not meet either specified image count threshold, this issue will again be reported in the "Fit a curve" and "Dose Calculator" dialogs.
  
 <WRAP round tip> <WRAP round tip>
Line 27: Line 27:
 </WRAP> </WRAP>
  
-==== Main GUI ====+==== Sample list in main GUI ====
 <WRAP group> <WRAP group>
 <WRAP half column> <WRAP half column>
Line 40: Line 40:
 <WRAP group> <WRAP group>
 <WRAP half column> <WRAP half column>
 +The "Sample Info" field in the "Dose-Response data" list has a background color of orange when an aberration does not meet QC thresholds. 
  
 +Because calibration curves are generally intended to be used repeatedly over a significant period of time, an additional warning will pop-up after the "OK" button is clicked to notify the user QC issues are present. At this time, you may opt to finish creating the curve anyway, or return to the "Fit a curve" dialog.
 </WRAP> </WRAP>
 <WRAP half column> <WRAP half column>
Line 51: Line 52:
 <WRAP group> <WRAP group>
 <WRAP half column> <WRAP half column>
-QC issues in the "Dose calculatordialog take into account additional "Aberration" QC thresholds. Note manually entered aberration will not generate a QC issue even if the manually entered value do not meet the specified QC thresholds. For a QC issue to be reported, the aberration must be related to an imported sample.+The "Name" field in the "DC Frequencies for Dose Estimationlist has background color of orange when an aberration does not meet QC thresholds.
 </WRAP> </WRAP>
 <WRAP half column> <WRAP half column>
 {{ file:DoseCalculatorQC.png?nolink }} {{ file:DoseCalculatorQC.png?nolink }}
 +</WRAP>
 +</WRAP>
 +
 +==== Dose estimation results in console ====
 +
 +<WRAP group>
 +<WRAP half column>
 +The "DC Frequency Name" field found in the [[main:console | console]] after performing [[main:estimatedose | dose estimation]] contains a "~" symbol if a QC issue is present.
 +</WRAP>
 +<WRAP half column>
 +{{ file:DoseEstimationResultQCFail.png?nolink }}
 +</WRAP>
 +</WRAP>
 +
 +==== Dose estimation report ====
 +
 +<WRAP group>
 +<WRAP half column>
 +A "Quality Control Issue" field is present under the heading "DC Frequency Information" in [[main:dosereport | dose estimation reports]]. The field contains text describing the specific QC issue observed.
 +</WRAP>
 +<WRAP half column>
 +{{ file:DoseEstimationReportQCFail.png?nolink }}
 </WRAP> </WRAP>
 </WRAP> </WRAP>
  